Pair check
Conflict: Specs conflict on at least one field.

Checked as a bank of 2 packs, which is the smallest number that accepts this inverter’s 130 amp charge current. Fewer packs still run the system, with the charge rate capped in inverter settings.

Full specifications: OutBack Radian GS8048A and Rich Solar 48V 100Ah.

The four checks

Voltage window: Overlapping window 44.8 to 58.4 V

The inverter operates from 40 to 64 volts and the battery cuts off outside 44.8 to 58.4 volts. Both stay inside 44.8 to 58.4 volts, which covers a normal LiFePO4 charge and discharge cycle with margin at both ends.

Match

Charge current: 130 A into a 200 A limit

The inverter tops out at 130 amps and the battery accepts 200 amps, so a default install cannot overrun the pack. Adding batteries in parallel raises the accepted current further.

Match

Surge rating: Battery surge figure unpublished

A surge to 12000 watts draws roughly 250 amps at 48 volts. This battery publishes a 200 amp continuous rating and no separate surge figure, and continuous is the wrong number to check a motor start against. Confirm the peak rating and its duration with the manufacturer before running motor loads.

Unverified

Closed-loop communication: No shared protocol

The inverter speaks Modbus and the battery speaks RS485. There is no common protocol between them, so closed-loop operation is off the table regardless of cabling.

Conflict

What this means when you install it

Set the inverter charge current to 130 amps or less. That is the inverter maximum, which this bank can absorb. Protect the battery run with a 250 amp Class T fuse and 4/0 AWG cable wired to a busbar rather than daisy chained, so all 2 packs share current evenly.

The inverter speaks Modbus and the battery speaks RS485. There is no common protocol between them, so closed-loop operation is off the table regardless of cabling.

Figures side by side

FieldOutBack Radian GS8048ARich Solar 48V 100Ah
Voltage window40 to 64 V44.8 to 58.4 V
Charge current130 A delivered200 A accepted (2 packs)
Peak draw12,000 W surgesurge unpublished
Usable capacityn/a10.24 kWh (2 packs)
CommsModbusRS485
Inverter source status: Provisional figure   Battery source status: Provisional figure   Confirm every figure against the document revision shipped with your unit before commissioning.

Manufacturer documents

Manufacturer documents: OutBack Power documentation. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.

Manufacturer documents: Rich Solar product pages. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.

Both units, current pricing

Prices on these move week to week, and the battery is usually the line item worth watching.

OutBack Radian GS8048A on AmazonRich Solar 48V 100Ah on AmazonComms cable

Affiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.

Other pairings for the Rich Solar 48V 100Ah

Questions people actually ask

Will the OutBack Radian GS8048A work with the Rich Solar 48V 100Ah?

Specs conflict on at least one field. Checked as a bank of 2 packs, which is the smallest number that accepts this inverter’s 130 amp charge current. Fewer packs still run the system, with the charge rate capped in inverter settings. The four checks below show which field produced that result.

What does this pairing cost to wire up?

Beyond the two units, a 250 amp Class T fuse and holder, 4/0 AWG battery cable cut to matched lengths, and a busbar if you are running 2 packs. A comms cable if you intend to attempt closed loop, and the pinout is rarely the same between brands.

Where does this pairing go wrong in practice?

The inverter speaks Modbus and the battery speaks RS485. There is no common protocol between them, so closed-loop operation is off the table regardless of cabling.

What charge current should I set?

The inverter tops out at 130 amps and the battery accepts 200 amps, so a default install cannot overrun the pack. Adding batteries in parallel raises the accepted current further.