MPP Solar LV2424 with EG4 PowerPro WallMount 48V 280Ah

Home / Comparisons / MPP Solar LV2424 with EG4 PowerPro WallMount 48V 280Ah
Pair check
Conflict: Specs conflict on at least one field.

Checked as a single pack, which covers this inverter’s charge current on its own.

Full specifications: MPP Solar LV2424 and EG4 PowerPro WallMount 48V 280Ah.

The four checks

Voltage window: No usable overlap

The inverter window of 20 to 32 volts and the battery window of 44.8 to 58.4 volts do not overlap usefully. One unit reaches its limit while the other is still in normal operation.

Conflict

Charge current: 80 A into a 200 A limit

The inverter tops out at 80 amps and the battery accepts 200 amps, so a default install cannot overrun the pack. Adding batteries in parallel raises the accepted current further.

Match

Surge rating: Battery surge figure unpublished

A surge to 4800 watts draws roughly 100 amps at 48 volts. This battery publishes a 200 amp continuous rating and no separate surge figure, and continuous is the wrong number to check a motor start against. Confirm the peak rating and its duration with the manufacturer before running motor loads.

Unverified

Closed-loop communication: Both speak RS485, no document names the pair

The inverter and the battery both support RS485. Neither manufacturer publishes a document naming the other unit, and a shared bus standard is not a shared message format. It may well work on the bench. Confirm the protocol setting with both manufacturers before relying on BMS control.

Unverified

What this means when you install it

Set the inverter charge current to 80 amps or less. That is the inverter maximum, which this bank can absorb. Protect the battery run with a 100 amp Class T fuse and 2 AWG cable.

The inverter and the battery both support RS485. Neither manufacturer publishes a document naming the other unit, and a shared bus standard is not a shared message format. It may well work on the bench. Confirm the protocol setting with both manufacturers before relying on BMS control.

Figures side by side

FieldMPP Solar LV2424EG4 PowerPro WallMount 48V 280Ah
Voltage window20 to 32 V44.8 to 58.4 V
Charge current80 A delivered200 A accepted
Peak draw4,800 W surgesurge unpublished
Usable capacityn/a14.34 kWh
CommsRS485CAN, RS485
Inverter source status: Provisional figure   Battery source status: Provisional figure   Confirm every figure against the document revision shipped with your unit before commissioning.

Manufacturer documents

Manufacturer documents: MPP Solar manuals. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.

Manufacturer documents: EG4 product and document library. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.

Both units, current pricing

Prices on these move week to week, and the battery is usually the line item worth watching.

MPP Solar LV2424 on AmazonEG4 PowerPro WallMount 48V 280Ah on AmazonComms cable

Affiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.

Other pairings for the EG4 PowerPro WallMount 48V 280Ah

Questions people actually ask

Will the MPP Solar LV2424 work with the EG4 PowerPro WallMount 48V 280Ah?

Specs conflict on at least one field. Checked as a single pack, which covers this inverter’s charge current on its own. The four checks below show which field produced that result.

What does this pairing cost to wire up?

Beyond the two units, a 100 amp Class T fuse and holder, 2 AWG battery cable cut to matched lengths, and a busbar if you are running 1 packs. A comms cable if you intend to attempt closed loop, and the pinout is rarely the same between brands.

Where does this pairing go wrong in practice?

The inverter and the battery both support RS485. Neither manufacturer publishes a document naming the other unit, and a shared bus standard is not a shared message format. It may well work on the bench. Confirm the protocol setting with both manufacturers before relying on BMS control.

What charge current should I set?

The inverter tops out at 80 amps and the battery accepts 200 amps, so a default install cannot overrun the pack. Adding batteries in parallel raises the accepted current further.

Field notes on this kind of problem