Dyness battery
A small rack module built to be stacked rather than used alone. The 54 volt ceiling matches the Pylontech convention rather than the 58.4 volt one, which is the setting most often got wrong.
Published figures
Usable capacity
2.4 kWh
Capacity
50 Ah
Voltage window
44.0 to 54.0 V
Max charge current
50 A
Max discharge current
50 A
Comms
CAN, RS485
Form factor
Server rack
Units in parallel
16
Source status: Provisional figure Typical street price $700 to $1,100. Charge and discharge limits are per unit. Wiring packs in parallel raises both.
How many you need, by inverter
One pack accepts 50 amps. An inverter that can deliver more than that needs more than one, or the charge rate capped in settings. Both are valid, and the second one costs you charging speed on the short days when you need it most.
No document tracked here names a specific inverter for closed-loop operation with this pack. That does not mean it will not work. It means nobody has published the test.
Where the figures come from
Manufacturer documents: Dyness product documentation. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.
Where to buy the Dyness B4850
Listings for the Dyness B4850 plus the rack hardware and cabling a clean install needs.
Affiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.
Questions people actually ask
How many Dyness B4850 packs do I need?
One pack accepts 50 amps and holds 2.4 kWh. Match the pack count to your inverter’s charge current first, then check the energy. A Sol-Ark 15K at 275 amps would take 6 of them to charge at full rate.
Does the Dyness B4850 do closed loop communication?
It publishes CAN, RS485. No document tracked here names a specific inverter, so any closed-loop claim needs confirming with both manufacturers before you rely on it.
How many can I wire in parallel?
The published limit is 16 units.
Which inverters pair cleanly with the Dyness B4850?
None of the inverters tracked here clear all four checks with this pack. Most land on unverified because nobody has published the comms or surge figure, which is a gap rather than a fault.