Victron Quattro 48/10000

Home / Inverters / Victron Quattro 48/10000
Detailed shot of capacitors and resistors on a circuit board, showcasing modern technology.
Illustrative equipment photography, not this model.
Victron inverter

The Quattro’s second AC input is the feature people buy it for: grid on one, generator on the other, with transfer handled internally instead of by a manual switch. Battery-side behaviour matches the MultiPlus-II, including the unusually generous 38 to 66 volt window that tolerates both a deeply drawn pack and a hot absorption stage.

Published figures

Continuous output
8,000 W
Surge output
20,000 W
Battery voltage window
38 to 66 V
Max charge current
140 A
Battery comms
VE.Bus, CAN
Output
120/240 V split phase
Grid interactive
Yes
PV input
External charge controller
Source status: Provisional figure Typical street price $3,500 to $4,500. Figures are recorded from manufacturer material and every one of them should be confirmed against the revision of the document that ships with your unit.

What this inverter will and will not do

  • It works alongside the utility, which means an interconnection agreement, a permit, and an inspection in most jurisdictions. Budget months, not weeks, for that process.
  • Output is 120/240 V split phase from one box, so standard household 240 V loads run directly.
  • Battery communication runs over VE.Bus, CAN, and closed loop still depends on both sides agreeing on a message format rather than only on a bus standard.
  • No solar charge controller is built in. A working system needs a separate MPPT, which is cost and cabinet space that is easy to leave out of a first budget.

Sizing a battery bank for it

This inverter delivers up to 140 amps of charge current, and that figure, not your daily energy use, sets the minimum pack count. Every battery below is shown at the smallest bank that can absorb the full charge rate.

BatteryPacks neededBank capacityVoltage windowCharge acceptedCommsResult
Pylontech US3000C27.1 kWh44.5 to 54.0 V148 ACAN, RS485Conflict
Dyness B485037.2 kWh44.0 to 54.0 V150 ACAN, RS485Unverified
SimpliPhi PHI 3.827.6 kWh44.0 to 57.6 V150 AnoneUnverified
Growatt ARK 2.5H37.7 kWh44.0 to 57.6 V150 ACAN, RS485Unverified
BYD Battery-Box Premium LVS 8.018.0 kWh40.0 to 57.6 V250 ACANUnverified
HomeGrid Stack’d 48V 9.6kWh19.6 kWh44.8 to 58.4 V150 ACAN, RS485Unverified
Pylontech US500029.6 kWh44.5 to 54.0 V200 ACAN, RS485Unverified
Freedom Won eTower 5210.0 kWh44.0 to 57.6 V200 ACANUnverified
EG4 LifePower4 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Conflict
EG4 LL-S 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
SOK 48V 100Ah Server Rack210.2 kWh46.4 to 56.0 V200 ACAN, RS485Conflict
Pytes E-BOX 48100R210.2 kWh44.8 to 58.4 V200 ACAN, RS485Conflict
Jakiper JK48V100 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Vatrer 48V 100Ah210.2 kWh40.0 to 58.4 V200 ARS485Conflict
Ruixu 48V 100Ah Server Rack210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
EG4 LifePower4 V2 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Conflict
Pytes V5 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Conflict
Pytes R-BOX 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
SOK 48V 200Ah110.2 kWh46.4 to 56.0 V200 ACAN, RS485Conflict
Jakiper JK48V200 48V 200Ah110.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
LiTime 48V 50Ah410.2 kWh40.0 to 58.4 V100 AnoneConflict
Vatrer 48V 200Ah110.2 kWh40.0 to 58.4 V200 ARS485Conflict
Ruixu Lithi-2 48V 200Ah110.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Trophy Battery 48V 100Ah210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
SunGold 48V 100Ah Rack210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Growatt ARK XH 5.1210.2 kWh44.0 to 57.6 V200 ACAN, RS485Unverified
Rich Solar 48V 100Ah210.2 kWh44.8 to 58.4 V200 ARS485Conflict
Basen 48V 200Ah110.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Gobel Power GP-SR1-48100210.2 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Victron Lithium Smart 48V 200Ah110.2 kWh40.0 to 57.6 V200 ACANUnverified
Fortress eFlex 5.4kWh210.8 kWh44.8 to 58.4 V200 ACAN, RS485Conflict
Discover AES 48-6650213.3 kWh42.0 to 57.6 V260 ACAN, ModbusUnverified
Discover AES 42-48-6650213.3 kWh42.0 to 57.6 V260 ACAN, ModbusUnverified
EG4 PowerPro WallMount 48V 280Ah114.3 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
EG4 WallMount Indoor 48V 280Ah114.3 kWh44.8 to 58.4 V150 ACAN, RS485Unverified
Seplos Mason 280 48V114.3 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
LiTime 48V 100Ah315.4 kWh40.0 to 58.4 V150 AnoneUnverified
BigBattery Owl 48V315.4 kWh44.8 to 58.4 V150 AnoneUnverified
BigBattery Etheron 48V 15kWh115.4 kWh44.8 to 58.4 V150 ACAN, RS485Unverified
CHINS 48V 100Ah315.4 kWh40.0 to 58.4 V150 AnoneUnverified
Redodo 48V 100Ah315.4 kWh40.0 to 58.4 V150 AnoneUnverified
Power Queen 48V 100Ah315.4 kWh40.0 to 58.4 V150 AnoneUnverified
ECO-WORTHY 48V 100Ah315.4 kWh40.0 to 58.4 V150 AnoneUnverified
HomeGrid Stack’d 48V 19.2kWh119.2 kWh44.8 to 58.4 V300 ACAN, RS485Unverified
Dyness PowerBox 48V219.2 kWh44.0 to 54.0 V200 ACAN, RS485Unverified
LiTime 48V 200Ah220.5 kWh40.0 to 58.4 V200 AnoneUnverified
BigBattery Rhino 2 48V228.6 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Fortress eVault Max 18.5kWh237.0 kWh44.8 to 58.4 V266 ACAN, RS485Conflict
Fortress eVault 18.5kWh237.0 kWh44.8 to 58.4 V200 ACAN, RS485Unverified
Rolls S-480 48V AGM241.2 kWh42.0 to 58.0 V170 AnoneUnverified
Packs needed is the smallest number that accepts this inverter’s 140 amp charge current, or the published parallel limit where that is lower, in which case the charge rate has to be capped in settings.

Fuse and cable for the battery run

Running flat out this inverter pulls about 167 amps at 48 volts, and a surge takes it to roughly 417 amps. Size the protection for the peak, not the average: a 250 amp Class T fuse at the battery positive terminal and 4/0 AWG cable on the battery run. Class T rather than a standard fuse because a 48 volt lithium bank can deliver enough short circuit current to arc across a fuse that lacks the interrupt rating. Confirm the sizing against your installation manual, which accounts for run length and ambient temperature.

Communication

Manufacturer documentation names Pytes E-BOX 48100R, BYD, Freedom Won for closed-loop operation. Any battery not on that list runs open loop until a document says otherwise.

Where the figures come from

Manufacturer documents: Victron manuals and datasheets. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.

Where to buy the Victron Quattro 48/10000

Current listings and prices for the Victron Quattro 48/10000 and the parts most builds need alongside it.

Check price on AmazonBattery cable and lugsClass T fuse and holder

Affiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.

Questions people actually ask

How many batteries does the Victron Quattro 48/10000 need?

Enough packs to accept 140 amps of charge current. With a 100 amp rack battery that is 2 of them. Fewer will run the system perfectly well with the charge rate capped in settings, and capping it costs you charging speed on short winter days.

What size fuse and cable does the Victron Quattro 48/10000 need?

It draws about 167 amps continuously at 48 volts and roughly 417 amps during a surge. That points at a 250 amp Class T fuse and 4/0 AWG cable for the battery run, sized for the fuse rather than the average load. Confirm against the figure in your installation manual, which accounts for run length and ambient temperature.

Which batteries have a documented pairing with the Victron Quattro 48/10000?

None of the batteries tracked here have a manufacturer document naming this inverter for closed-loop operation. That is a documentation gap, not a verdict on the hardware.

Can the Victron Quattro 48/10000 run a well pump?

It surges to 20,000 watts, about 417 amps from the battery. Whether the pump starts depends on the pack as much as the inverter, because the BMS is what interrupts a surge it is not rated for. The pairing pages check that figure per battery. No battery tracked here publishes a surge rating that clears it at the bank sizes shown, which is a documentation gap rather than a verdict on the hardware. Ask both manufacturers for the peak figure and its duration before committing to a motor load.