Pytes appears on more manufacturer compatibility lists than almost any other rack battery in this price class, which is the entire reason to consider it over a cheaper import. You are not paying for better cells. You are paying for somebody else having done the protocol testing and published the result.
Published figures
- Usable capacity
- 5.12 kWh
- Capacity
- 100 Ah
- Voltage window
- 44.8 to 58.4 V
- Max charge current
- 100 A
- Max discharge current
- 100 A
- Comms
- CAN, RS485
- Form factor
- Server rack
- Units in parallel
- 15
How many you need, by inverter
One pack accepts 100 amps. An inverter that can deliver more than that needs more than one, or the charge rate capped in settings. Both are valid, and the second one costs you charging speed on the short days when you need it most.
Communication
Manufacturer documentation names Victron MultiPlus-II 48/5000, Victron Quattro 48/10000, Sol-Ark 12K, Deye SUN-12K-SG04LP3-US for closed-loop operation with this pack.
Where the figures come from
Manufacturer documents: Pytes download centre. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.
Where to buy the Pytes E-BOX 48100R
Listings for the Pytes E-BOX 48100R plus the rack hardware and cabling a clean install needs.
Check price on AmazonServer rack for batteryBattery interconnect cablesAffiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.
Questions people actually ask
How many Pytes E-BOX 48100R packs do I need?
One pack accepts 100 amps and holds 5.12 kWh. Match the pack count to your inverter’s charge current first, then check the energy. A Sol-Ark 15K at 275 amps would take 3 of them to charge at full rate.
Does the Pytes E-BOX 48100R do closed loop communication?
It publishes CAN, RS485. Manufacturer documentation names Victron MultiPlus-II 48/5000, Victron Quattro 48/10000, Sol-Ark 12K, Deye SUN-12K-SG04LP3-US specifically.
How many can I wire in parallel?
The published limit is 15 units.
Which inverters pair cleanly with the Pytes E-BOX 48100R?
Sol-Ark 12K, Sol-Ark 15K, Victron MultiPlus-II 48/5000, Deye SUN-12K-SG04LP3-US, Sol-Ark 5K, Sol-Ark 8K, Victron MultiPlus-II 48/3000, Victron MultiPlus-II 48/8000, Deye SUN-5K-SG04LP1, Deye SUN-8K-SG04LP1 align on all four checked fields at the bank size shown on each pairing page.