Illustrative equipment photography, not this model.
ECO-WORTHY battery
Turns up often in forum questions because it is cheap and widely stocked. No communication port, so pair it with hand set voltage limits and a shunt monitor.
Published figures
Usable capacity
5.12 kWh
Capacity
100 Ah
Voltage window
40.0 to 58.4 V
Max charge current
50 A
Max discharge current
100 A
Comms
none published
Form factor
Bare case
Units in parallel
4
Source status: Provisional figure Typical street price $600 to $950. Charge and discharge limits are per unit. Wiring packs in parallel raises both.
How many you need, by inverter
One pack accepts 50 amps. An inverter that can deliver more than that needs more than one, or the charge rate capped in settings. Both are valid, and the second one costs you charging speed on the short days when you need it most.
No document tracked here names a specific inverter for closed-loop operation with this pack. That does not mean it will not work. It means nobody has published the test.
Where the figures come from
Manufacturer documents: ECO-WORTHY product pages. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.
Where to buy the ECO-WORTHY 48V 100Ah
Listings for the ECO-WORTHY 48V 100Ah plus the rack hardware and cabling a clean install needs.
Affiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.
Questions people actually ask
How many ECO-WORTHY 48V 100Ah packs do I need?
One pack accepts 50 amps and holds 5.12 kWh. Match the pack count to your inverter’s charge current first, then check the energy. A Sol-Ark 15K at 275 amps would take 6 of them to charge at full rate, past the published parallel limit of 4, so that pairing charges at a capped rate.
Does the ECO-WORTHY 48V 100Ah do closed loop communication?
No, there is no communication port at all. Every pairing with this pack is open loop, and the inverter estimates state of charge from terminal voltage, which is unreliable through the middle of a LiFePO4 curve.
How many can I wire in parallel?
The published limit is 4 units.
Which inverters pair cleanly with the ECO-WORTHY 48V 100Ah?
None of the inverters tracked here clear all four checks with this pack. Most land on unverified because nobody has published the comms or surge figure, which is a gap rather than a fault.