Fortress publishes a real document library, per product, with revision dates, which is rarer than it should be and is why several pairings on this site resolve to match rather than unverified. The eVault is heavy enough that the install location is a structural question, not a preference. Check the floor before you check the wiring.
Published figures
- Usable capacity
- 18.5 kWh
- Capacity
- 360 Ah
- Voltage window
- 44.8 to 58.4 V
- Max charge current
- 133 A
- Max discharge current
- 133 A
- Comms
- CAN, RS485
- Form factor
- Floor standing
- Units in parallel
- 10
How many you need, by inverter
One pack accepts 133 amps. An inverter that can deliver more than that needs more than one, or the charge rate capped in settings. Both are valid, and the second one costs you charging speed on the short days when you need it most.
Communication
Manufacturer documentation names Sol-Ark 12K, Sol-Ark 15K, Schneider XW Pro 6848, Victron MultiPlus-II 48/5000 for closed-loop operation with this pack.
Where the figures come from
Manufacturer documents: Fortress Power document library. Figures here should be read against the revision that covers your serial number, because manufacturers revise specifications without changing the model name.
Where to buy the Fortress eVault Max 18.5kWh
Listings for the Fortress eVault Max 18.5kWh plus the rack hardware and cabling a clean install needs.
Check price on AmazonServer rack for batteryBattery interconnect cablesAffiliate links. As an Amazon Associate this site earns from qualifying purchases, at no extra cost to you. Prices and stock change often, and a listing appearing here is not a statement that the pairing above is approved.
Questions people actually ask
How many Fortress eVault Max 18.5kWh packs do I need?
One pack accepts 133 amps and holds 18.5 kWh. Match the pack count to your inverter’s charge current first, then check the energy. A Sol-Ark 15K at 275 amps would take 3 of them to charge at full rate.
Does the Fortress eVault Max 18.5kWh do closed loop communication?
It publishes CAN, RS485. Manufacturer documentation names Sol-Ark 12K, Sol-Ark 15K, Schneider XW Pro 6848, Victron MultiPlus-II 48/5000 specifically.
How many can I wire in parallel?
The published limit is 10 units.
Which inverters pair cleanly with the Fortress eVault Max 18.5kWh?
Sol-Ark 12K, Sol-Ark 15K, Victron MultiPlus-II 48/5000, Schneider XW Pro 6848, Sol-Ark 5K, Sol-Ark 8K, Victron MultiPlus-II 48/3000 align on all four checked fields at the bank size shown on each pairing page.